Small Medical Waste Incineraotr for COVID-19 Bio Hazardous Medical Waste

HICLOVER – Medical Environmental  Model YD-20 Picture Burning Rate Average 20 kgs/hour Feed Capacity Average 60 kgs/feeding Primary Combustion Chamber 360 Liters Secondary Combustion Chamber 200 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 1.0 Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) Average 13.3 kg/hour Gas Consumption (Natural Gas) *** Internal Dimensions 100 x 60 x…

Read More

50-100-150-200 Kgs per Hour Solid Waste Incinerator on Sale

Waste Incinerator Model TS150 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.Primary Combustion Chamber: ※Main Feature:– Double Combustion Chamber– Double Italy Burner– Smoke Filter…

Read More

Incinerator for medical wastes 30kgs per hour

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air FiltersNanjing Clover Medical Technology Co.,Ltd.Tel:  +86-25-8461 0201   Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Model TS30 PLC Main Product List per 01 set Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator PLC Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil/gas burner: 02 sets Oil Tank (if oil fuel): 100Liters

Read More

Industrial MultiWaste Incinerator System

Design, installation and commissioning of multi industrial waste incinerator. Capacity: 315 KG/HOUR SOLID WASTE/ OR 200 LITRES/HOUR LIQUID WASTE (with dual chamber system)1st chamber-870 Deg.C – 900 Deg.C2nd chamber-1000 deg.C – 1200 Deg.CIncinerator should have following criteria:radiant temperatureAdvanced gas treatment system to avoid emission of toxic gases (scrubbing system).Low consumption high efficiency compact automatic burning system.Low running and maintenance costsFully automatic and simple to operate control panelAfterburner PreheatDense refractory concrete lining rated at 1600 CSolid Hearth to allow maximum BurnoutLarge Top opening lid for easy loadingWide door for ash removalOptional Stainless Steel CasingHeat recovery optionIt has special metal seal structure, refractory, bricking art, air distribution of multi-stream circling and advanced end-gas treatment without second pollution.  Provide automatic control for users.  The system should passed appraisal, fill up national blank and become substitute for import products. It should have notable economic and social benefit.          1). Ignition transformer             2). Ignition rod             3). Digital temperature indicator             4). Temperature controller variable             5). Thermo couple (heat sensor)             6). Flame detector             7). U.V. Sensor             8). Electromechanical Solenoid valve             9). Low and high fire control governor.            10). Eye hole for visual indication.            11). Venturi Scrubber filtration system for smoke control emission.            12). Liquid spraying nozzles with the capacity of 25 % (20 nozzles).

Read More